* Supported the V430-F series Auto Focus Multi Code Reader. * Supported the FHV7 series Smart Camera. * Supported the K6PM series Control Panel Monitoring Device.

* Solved the problem that memory leak might occur when the project file could not be loaded. * Supported the new inverter 3G3RX2-series * Solved the problem that CX-Integrator might terminate abnormally when device parameters of the EJ1N-HFUB-DRT are copied. * Solved the problem that data could not be transferred to the comment memory immediately after clearing all memory. * Solved the problem in Ver.9.72 that arithmetic expressions cannot be used as the index of array variables in the ST program. * Solved the problem that no error is detected in program check even when an array variable without address assignment is used in a ST program/ST action/ST transition. * Solved the problem that transferring CP1E programs to CX-Simulator might fail when the programs include interruption tasks. * Solved the problem that a fatal error might occur in the PLC if a structure BOOL type member is used for the IF statement condition for the FBST program in CJ2H/CJ2M.

* Solved the problem that program errors cannot be detected if an array of variable type index is specified in the DIFU/DIFD instruction operands in the FB ladder. * Solved the problem that an error occurs in the program check for a program with the maximum display capacity in the Memory view, when interrupt tasks and FB definitions are used simultaneously in a PLC with an area for FB only. * Solved the problem that the UM size displayed in the FB Memory view of CP1 might be incorrect when there is an FB definition and no FB instance. * Solved the problem that CX-Programmer might terminate abnormally, when a program that included FB instance was uploaded from the PLC. * Solved the problem that an error might not be detected in program check even though input condition of the FB instance was not correct. * Solved the problem that timer/counter numbers were determined incorrectly as duplicated with CIO address when the CIO address was specified as automatic allocation area. * Solved the problem that a fatal error occurred on the PLC after the project was downloaded, becauseDR0+,IR00 that was specified for instruction's parameter was not detected in error check. * Solved the problem that CX-Programmer terminated abnormally or became inoperable when a project with a long project name or a long PLC name was loaded. When CX-One Lite is installed: CP1L-M => CP2E-S When CX-One is installed: CJ1M-CPU11 => CJ2M-CPU11